This flight was an enginnering test conducted for the National Aeronautics and Space Administration (NASA) by the National Scientific Balloon Facility (NSBF). The test was part of a flight program implemented by NASA between 1989 and 1991 to determine the effect of flying at an increased flight stress index value as well as answering several other balloon performance questions. The NASA flight stress index, was developed in 1986 to provide an index of the relative stress magnitudes along a balloon gore as a function of altitude and to provide a means of predicting flight performance.
FLIGHT AND TESTING PLAN
The primary objectives of the test flights were to increase the flight stress index through the increase in suspended payload to determine the performance capabilities of balloons made of Astrofilm "E2" and Stratofilm-372 as compared to the older Stratofilm in use, as well as to provide further validation of the flight stress index as an analysis/predictive tool.
The entire program included the realization of six flights. The first four flight tests would use 23 million cubic feet (mcf) class balloons. The first series of two were to be conducted with a suspended payload of 6,000 lbs at a flight stress index value of approximately 3,400 psi. If successful, the second series of two flight tests would be conducted with a suspended payload of 7,000 lbs. and a flight stress index value of approximately 3,800 psi. Depending on the success of the first series, the final two flights would be conducted using the 28 mcf EXP class design with a suspended payload of 7,000 lbs. and a flight stress index value of approximately 3800 psi. Both Winzen and Raven balloons were used for the flight tests.
Secondary objectives of the test series were to provide: 1) balloon structural and vertical performance data on the balloon's dynamic response to very large and rapid changes in payload weight; 2) balloon structural performance data for balloons with payloads significantly less than the minimum recommended or "design" payload; 3) evaluation of a newly developed thermistor reel profiler system for use in obtaining balloon and atmospheric temperatures; and 4) balloon gas temperature data for the determination of balloon gas stratification for use in balloon vertical performance model studies.
The planned flight profile called for the balloon to ascend under normal NSBF operational control and achieve float stabilization. After approximately 1 hour at float, a large and rapid ballast drop of 2,000 lbs. was to be initiated with successive large ballast drops made until all ballast was depleted. Completion of all ballast drops would thus achieve a suspended payload several hundred pounds less than the minimum design payload. Prior to termination of the flight, the balloon gas temperature would be vertically profiled for gas stratification data. The test flight would then be terminated and the engineering payload recovered.
ENGINEERING PAYLOAD USED FOR THE TESTS
To accomplish the objectives of the program each balloon carried the same engineering gondola containing:
- Two ambient air thermistors located 500' below the gondola;
- One up looking, pan/tilt video camera;
- Four up looking super 8 cameras working at different frame rates and activated during diffferent phases of the flight;
- One balloon gas temperature profiler;
- One full gondola diagnostics package (GDP) for termination event;
- One GDP lower unit for ballast drop;
- One Stow Away Special (SAS) with peak/hold circuit;
- One SAS with standard accelerometer and timing system for launch accelerations;
- One down radiometer.
In addition to the above instrumentation, meteorological conditions under the balloon for the entire ground track and all operational housekeeping data were recorded.
Balloon launched on: 5/5/1990 at 13:56 utc
Launch site: Scientific Flight Balloon Facility, Fort Sumner, (NM), US
Balloon launched by: National Scientific Balloon Facility (NSBF)
Balloon manufacturer/size/composition: Zero Pressure Balloon Winzen - 23.300.000 cuft - Three capped
Balloon serial number: W23.50-3 Serial Nº 8
Flight identification number: 287NT
End of flight (L for landing time, W for last contact, otherwise termination time): 5/5/1990 at 20:00 utc
Balloon flight duration (F: time at float only, otherwise total flight time in d:days / h:hours or m:minutes - ): 7 h
Landing site: 10 miles W of Tulia, Texas, US
Payload weight: 6.000 lbs
Overall weight: 10.806 lbs
This was the second flight of the testing program. The balloon was launched from Fort Sumner, New Mexico as mission 287-NT at 13:57 UTC on May 5, 1990. The flight system consisted of a three capped Winzen 23.3 mcf balloon, and a suspended engineering payload of 6,000 lbs. The ballast systems were the same as used for the previous test flights: an outer ballast conduit, an inner conduit and a normal NSBF ballast hopper. The gross load of the system was 9,825 lbs. Ten percent free lift was used for a total gross inflation of 10,806 lbs.
Approximately 600 lbs. of ballast was dropped on ascent due to the balloon exhibiting a slowing in its ascent rate at approximately 36,000 ft. The balloon arrived at its initial float altitude of 115,000 ft. 3 hours and 40 min. after launch. The balloon was allowed to stabilize at float for 1 hr. 40 min. prior to any further ballast drops.
The first ballast drop of 2,000 lbs. resulted in an ascent rate of approximately 3,500 ft./min. and a new altitude of 121,OOO ft. A successive ballast drop of 1,500 lbs. was successfully conducted approximately 8 min. later with an ascent rate of approximately 3,000 ft./min. and a final float altitude of 126,000 ft. being observed. The final suspended payload after all ballast drops was 1,670 lbs., which was 1,555 lbs. less than the minimum design payload of 3,225 lbs.
The flight was successfully terminated at 19:59 UTC.
9834If you consider this website interesting or useful, you can help me to keep it up and running with a small donation to cover the operational costs. Just the equivalent of the price of a cup of coffee helps a lot.